TP Group logo TP-GROUP - Your Partner in Power Supplies & OEM Production
Power Supplies, DIN RAIL modules, Custom design Power Supplies, Automotive, Battery Charger, Xenon Lamp Power Supply, LED Driver, OEM Production
back to the TP Group homepage See the TP Group company profile here To the TP Group Power Supply catalog pages Read more about our special products here learn more about our service here TP Group contact details
185/250W Multiple Output Power Supply - - - Series 185U / 250U

  • Adjustable main output voltage
  • Overload protection
  • Overvoltage protection
  • Buit-in Brown-out protection
  • Short circuit protection
  • Remote sense on main output
  • Over temperature protection ( Optional )
  • Power good signal ( Optional )

  • Computer Peripherals / LAN and HUB
  • Test- & Industrial Equipment
  • Medical Instruments
  • Telecommunication equipment

input

  • Voltage: 90-264 Vac, universal input
  • Frequency: 47-63 Hz
  • Current: 3 A rms. Max @115 Vac and 185W load.
  • Current: 4 A rms. Max @115 Vac and 250W load.
  • Current: 2 A rms. Max @230 Vac and 185W load.
  • Current: 2.5 A rms. Max @230 Vac and 250W load.
  • Inrush surge current: 40A typical, cold start@25 °C, 115Vac

  • Output Power: 185Watt max (convection rating)
  • Output Power: 250Watt max (forced air 30cfm convection )
  • Line regulation: +/- 0.5 % typical
  • Load regulation: main outputs +/- 5%, aux outputs +/- 10% typical (note1)
  • Short circuit protection.
  • Noise & Ripple: 1% Typical at full load (note2)
  • Overshoot / Undershoot: 10% max. @ Turn-on / Turn-off

Dimensions: 4.5"x8"x1.67" (WxLxH)

Available models:

Model # No. Voltage Load Range ( A ) Load
Regulation
(%) ( Note 1 )
Ripple & Noise
( mVp-p )
( Note 2 )
( VDC ) Min.

Max.
( Convection Rating )

DTEC-185U / 250U Single Output Voltage / Current Rating Charts
  185U/250U 185U/250U 185U 250U 185U/250U 185U/250U 185U/250U
S0 1 +3.3V 0 35 46 ± 3% 100mV
S1 1 +5V 0 35 46 ± 3% 100mV
S2 1 +12V 0 15.42 29.84 ± 3% 180mV
S3 1 +15V 0 12.34 16.67 ± 3% 225mV
S4 1 +24V 0 7.7 10.42 ± 3% 240mV
S5 1 +48V 0 3.86 5.21 ± 3% 480mV
DTEC-185U / 250U Dual Output Voltage / Current Rating Charts
D12 1
2
+5V
+12V
1.08
0.8
18
8
25
11
± 5%
± 10%
100mV
180mV
D14 1
2
+5V
+24V
1.8
0.4
18
4
25
5.5
± 5%
± 10%
100mV
240mV
D1B 1
2
+5V
-5V
1.85
1.85
18.5
18.5
25
25
± 5%
± 10%
100mV
150mV
D2C 1
2
+12V
-12V
0.8
0.8
7.7
7.7
10.5
10.5
± 5%
± 10%
180mV
180mV
D24 1
2
+12V
+24V
0.8
0.4
7.4
4
10
5.5
± 5%
± 10%
180mV
240mV
DTEC-185U / 250U Tripple Output Voltage / Current Rating Charts
T12C 1
2
3
+5V
+12V
-12V
1.8
0.75
0.14
16
7.5
1.4
25
9
2
± 5%
± 10%
± 10%
100mV
180mV
180mV
T12B 1
2
3
+5V
+12V
-5V
1.8
0.75
0.14
17
7.5
1.4
25
10
2
± 5%
± 10%
± 10%
100mV
180mV
100mV
T124 1
2
3
+5V
+12V
+24V
1.8
0.65
0.14
16
6
1.4
24
7
2
± 5%
± 10%
± 10%
100mV
180mV
240mV
T012 1
2
3
+3.3V
+5V
+12V
1.6
1.6
0.3
16
16
3
25
20
5
± 5%
±5%
± 10%
100mV
100mV
180mV
T14C 1
2
3
+5V
+24V
-12V
1.8
0.35
0.14
17
3.5
1.4
24
4.5
2
± 5%
± 10%
± 10%
100mV
240mV
180mV
DTEC-185U / 250U Quad Output Voltage / Current Rating Charts
Q12CB 1
2
3
4
+5V
+12V
-12V
-5V
1.6
0.7
0.15
0.15
15
7
1.5
1.5
23
8.5
2
2
± 5%
± 10%
± 10%
± 10%
100mV
180mV
180mV
100mV
Q12C4 1
2
3
4
+5V
+12V
-12V
+24V
1.6
057
0.15
0.15
15
4.6
1.5
1.5
22
6
2
2
± 5%
± 10%
± 10%
± 10%
100mV
180mV
180mV
240mV
Q12C5 1
2
3
4
+5V
+12V
-12V
+48V
1.6
0.5
0.15
0.1
13
4.5
1.5
1
19
6
2
1.3
± 5%
± 10%
± 10%
± 10%
100mV
180mV
180mV
480mV
Q02C1 1
2
3
4
+3.3V
+12V
-12V
+5V
1.3
0.5
0.14
1.2
13
5
1.4
12
18
6
2
18
± 5%
± 10%
± 10%
±5%
100mV
180mV
180mV
100mV
Q13D4 1
2
3
4
+5V
+15V
-15V
+24V
1.6
0.35
0.15
0.15
15
3.5
1.5
1.5
20
5
2
2
± 5%
± 10%
± 10%
± 10%
100mV
180mV
180mV
240mV

Note 1: Cross/Load regulation tested at 10 -100% of rated load and other outputs are set to 50% of rated load.

Note 2: Peak-to-peak for 185W (convection rating) 250W ( with 30cfm forced air ) @115Vac min. ; measurements with a 20mHz bandwidth and terminated with a 10uF electrolytic cap. in parallel with a 0.1uF ceramic cap. 

environmental

  • Operating temperature:0°C to 50°C ambient, each output derated 2.5% per °C from 50°C to 70°C
  • Storage temperature:-40°C to 85°C
  • Humidity:Operating, non-condensing, 5% to 95%
  • Vibration:Random operating 2.4 grms/max. 3 axes 50~500hz 10 minutes/axis
  • Shock:Operating half sine 20 gpk/max. 3 axes 10ms 6 shocks total

general

  • Remote sense: 250mV ± 50mV @ V1 at full load
  • Turn-on time: 1sec max at full load @ 115Vac
  • Hold-up time: 16ms typical at full load @ 115Vac
  • Mtbf demonstrated: > 100,000 hours at full load and 25 °C ambient conditions

Electromagnetic compatibility specifications

  • EMI conducted/radiated: fcc & cispr class b
  • Designed to meet en61000-3-3,-4-2,-3,-4,-5,-6,-8,-11

 

CONNECTOR TYPE & PIN ASSIGNMENTS

I/O connectors are all Screw terminal blocks with a pin assignment conform the table below.

Con1 = AC input
Pole1 ( pin1)
FG
Pole2 ( pin2)
Neutral
Pole3 ( pin3)
Line
 
Con2 = Output
1 Output:
Pole 1~4 ( Pin 1 ~ 10 )
V1
Pole 5~8 ( Pin 11 ~ 20 )
RET
2 Outputs ( V2 positive ):
Pole 1~2 ( Pin 1 ~ 5 )
V1
Pole 3,4 ( Pin 6 ~ 10 ), Pole 7,8 ( Pin 16 ~ 20 )
RET
Pole 5~6 ( Pin 11 ~ 15 )
V2
2 Outputs ( V2 negative ):
Pole 1~2 ( Pin 1 ~ 5 )
V1
Pole 3~6 ( Pin 6 ~ 15 )
RET
Pole 7~8 ( Pin 16 ~ 20 )
V2
3,4 Outputs
Pole 1~3 ( Pin 1 ~ 5 )
V2
Pole 3~6 ( Pin 6 ~ 15 )
RET
Pole 7~8 ( Pin 16 ~ 20 )
V1
Pole 3~6 ( Pin 6 ~ 15 )
V4
Pole 7~8 ( Pin 16 ~ 20 )
V3
 
Con3 = Special function
Pin1
S-
Pin2
S+
Pin3
R.C.
Pin4
AC Fail
Pin5
RET
Pin6
Power Good

 

Mechanical drawing and dimensions:


lte45fs-b

CONTACT